Isolation Transformer 3600W, 230V or 115V

✅ Adjustable input & output 115V or 230V | ✅ Prevention of galvanic corrosion | ✅ Soft start function


Varianten-ID 14191

Weitere Ausführungen

excl. ${ $store.getters.currentItemVariation.prices.default.vat.value }% MwSt. excl. Shipping

Weight , Versand als Paket

Transportzeit 1-2 Werktage**

Add suitable accessories

Isolation Transformer 3600W for 115V or 230V AC

Toroidal and SoftStart Function

Ship, Boats, Industrie

Safety and prevention of galvanic corrosion
The isolation transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms.

Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire on board results in an unsafe situation because GFCI’s will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

Galvanic Corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically onducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc.

It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCI’s will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an isolation transformer to connect to the shore-side supply. The isolation transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The isolation transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.

Soft Start Funktion is a standard feature of our isolation transformer. It will prevent the shore power fuse from blowing due to the inrush current of the transformer, which would otherwise occur.

It is also recommended, for optimal safety, to connect the secondary neutral of the transformer to ground when the boat is out of the water.

Adjustable
The Isolation Transformer can be used for different input and output voltages. See below:
Input 115V to Output 115V (32A)
Input 115V to Output 230V (16A)
Input 230V to Output 230V (16A)
Input 230V to Output 115V (32A)

Delivery contain::

  • Isolation Transformer 3600W

Further helpful Informations you will find in our FAQ under the following link: FAQ

  • Input Voltage: 115 or 230V AC
  • Output Voltage: 115 or 230V AC
  • Frequency: 50/60Hz
  • Rating: 32A@115V / 16A@230V
  • Softstart Function: yes
  • Transformator type: Toroidal
  • Input circuit breaker: yes
  • Housing: Aluminum
  • Protecion category: IP21
  • Weight: 23kg (without carton)
  • Dimension: 362 x 258 x 218 (HxWxD)

Varianten ID

14191

Sie haben noch Fragen zum Ablauf der Bestellung oder zum Artikel?

Kontaktieren Sie doch einfach einen Mitarbeiter aus unserem Kundenserviceteam.

Wir sind für Sie telefonisch von Mo. bis Do. von 8:00 bis 12:30 Uhr und 13:30 bis 18:00 Uhr sowie
Freitags von 8:00 bis 12:30 Uhr und 13:30 bis 17:00 Uhr erreichbar.
Tel.: 06024 6341 560 oder per Fax unter 06024 6341 569
Natürlich stehen wir Ihnen auch per e-mail zur Verfügung: kontakt@fraron.de


Sie würden die Ware gerne vorher ansehen oder sich persönlich vor Ort beraten lassen?

Kein Problem, gerne können Sie sich alle Produkte in unserer Ausstellungsfläche ansehen.
Wir stehen Ihnen natürlich persönlich für ein Beratungsgespräch zur Verfügung.
Mo. bis Do. von 8:00 bis 12:30 Uhr und 13:30 bis 18:00 Uhr
Freitags von 8:00 bis 12:30 Uhr und 13:30 bis 17:00 Uhr


Welche Zahlungsarten stehen Ihnen zur Verfügung?

Barzahlung / EC Kartenzahlung bei Abholung in der Ladenfiliale in Schöllkrippen
Überweisung / Vorkasse
Nachnahme (Sie zahlen bei Erhalt direkt beim Paketzusteller)
PayPal inklusive Käuferschutz (für Länder der EU sowie Liechtenstein, Norwegen, Island)
Kreditkarte (Visa / Master)

Wie lange dauert der Versand der Ware?

Der Lagerstatus ist online auf der jeweiligen Produktseite angegeben. Lagernde Produkte, werden in Abhängigkeit von der Zahlart sofort oder nach Zahlungseingang versendet. Der Versand paketversandfähiger Waren erfolgt in alle Lieferländer per DHL. Die Paketlaufzeiten in Deutschland liegen bei 1-2 Werktagen. DHL stellt auch Samstag in Deutschland zu. Speditionsgut versenden wir über die Spedition Emons, die Laufzeiten liegen bei 2-3 Werktagen innerhalb Deutschlands, im Ausland kann dies nicht pauschal angegeben werden, bitte sprechen Sie uns an.

<div class="pdf"> <a href="https://www.dropbox.com/s/oi1v1ed6b8o1ils/ACAC2000VTR.pdf?dl=0">Manual</a> </div>

 high quality goods
 huge warehouse
 best service
NACHNAME RECHNUNG